GAO Qiangwei,ZHUO Chengcheng,LIU Yichao,YUE Yang
Abstract:To accurately assess the power quality status of a system,a comprehensive power quality evaluationmethod based on a combined weighting approach and the normal cloud model was proposed. Initially,acomprehensive evaluation framework for power quality was established,encompassing three key dimensions:amplitud...
更多
Number of views:872 Amount of downloads:3454
-
ZHOU Weiyi,LOU Chengyu,WEI Dong,XU Yudong
Abstract:To optimize the performance of proton exchange membrane fuel cell(PEMFC)systems and enhancefuel utilization,a calculation model for fuel utilization based on internal resistance characteristics was established.The effects of operating conditions—specifically,operating temperature and humidity—on internal r...
更多
Number of views:773 Amount of downloads:3631
-
XIAO Lisha,CHENG Jiangzhou,BAO Gang,ZHU Changdong,ZHANG Bowen,WANG Xiao
Abstract:With the increasing complexity of distribution grids due to the integration of distributed powersources,an improved matrix acceleration state enumeration method was proposed to enhance the computationalefficiency and accuracy of reliability assessment when integrating distributed energy into distribution g...
更多
Number of views:672 Amount of downloads:3385
-
CHEN Wen,LI Pengcheng,ZHANG Hua,ZUO Zhengqin,HUANG Lilin
Abstract:Aiming at the problems of significant nonlinear metering error and low overshoot response ratefaced by electric vehicle charging equipment in complex environments,an out-of-tolerance metering dynamicmodeling method integrating the neural ordinary differential equations(ODE)and vehicle-pile-cloud synergy da...
更多
Number of views:665 Amount of downloads:3117
-
XIE Xiaofei,LE Jiangyuan,LI Fei
Abstract:The back electromotive force(EMF)increases with the speed of the motor,that is,the faster thespeed,the greater the back EMF,and when running at low speed,the traditional permanent magnet synchronousmotor(PMSM)has no position sensor control technology,and the signal-to-noise ratio of the useful signal is ver...
更多
Number of views:1625 Amount of downloads:8377
-
WANG Yiming,XU Po,YANG Ke,XIA Kun,WANG Jingxia
Abstract:A 2 kV photovoltaic grid-connected inverter system based on a five-level active neutral-pointclamped(ANPC-5L)topology was designed for high-power,high-voltage applications. This topology significantlyimproved the system efficiency and reliability by increasing the number of output levels and reducing the sw...
更多
Number of views:1699 Amount of downloads:8228
-
DING Jinjin,PENG Bo,ZHANG Feng,MAO Xun
Abstract:To address the large inrush current during the switching of a virtual synchronous generator(VSG)from off-grid to grid-connected,and the stability issues of traditional pre-synchronization schemes,a controlmethod for the phase-locked loop(PLL)pre-synchronization unit to be cut off in non-grid-connected time ...
更多
Number of views:1475 Amount of downloads:7502
-
ZHANG Sen,LÜ Zhenhua,LI Qiang
Abstract:After frequency disturbances occur in the external power grid,grid-forming converters(GFCs)areprone to synchronization instability. Analysis shows that adding a low-pass filter(LPF)to the active loop can causeconflicts between the transient stability and frequency stability of GFC,while adding LPF to the re...
更多
Number of views:1589 Amount of downloads:7489
-
TIAN Jiahui,QI Xiaoguang,ZHAO Kailin,XU Tianfeng,CHEN Yueqing,LI Linjing
Abstract:Junction temperature is a key indicator of the health status of SiC MOSFET,and real-timemonitoring of junction temperature is an important foundation for condition monitoring,health management andlifetime prediction. The real-time monitoring of junction temperature was investigated based on the on-resistanc...
更多
Number of views:1800 Amount of downloads:8642
-
LI Li,PANG Shengyang,ZHONG Ronghao,HUANG Qingdan,ZHANG Liping,ZHANG Yachao
Abstract:With the increase in electricity demand,the rising maintenance costs of substation projects have putpower grid companies under huge market pressure. Traditional cost methods cannot meet the needs of modernmarkets,so the construction of intelligent cost calculation models is the key to realize the modernizat...
更多
Number of views:1525 Amount of downloads:6765
-
SUN Xiangfei,LI Ping,DA Guangjun,DOU Xiaochang
Abstract:Due to the large rotational inertia of synchronous machines,frequency changes caused by faults areminimal. In contrast,new energy systems have smaller rotational inertia,which can result in more significantfrequency variations during faults. These larger frequency fluctuations inevitably lead to changes in ...
更多
Number of views:1495 Amount of downloads:7674
-
ZHANG Hengrong,ZHENG Youzhuo,DUAN Liwei,LONG Zhi,WENG Di
Abstract:Aiming at the problem of peak-valley difference increase and voltage violation caused by large-scalefluctuation of network power in multi-time sections under high-proportion photovoltaic distribution network,apeak-shaving optimization strategy based on feeder load power control and multi-type resources was ...
更多
Number of views:1203 Amount of downloads:6705
-
XU Yang,YUAN Hang,ZENG Haijian,ZHANG Mingmin
Abstract:With the rapid development of new distribution networks,an increasing number of fluctuatingcomponents such as distributed generation,electric vehicles,and photovoltaic systems are being integrated. Thisnecessitates the widespread deployment of distributed energy storage systems to ensure the secure and reli...
更多
Number of views:1355 Amount of downloads:6720
-
HUO Tingting,JIA Zhilong,YAN Yong,ZHANG Qing
Abstract:To enhance the trajectory tracking control stability of driverless vehicles under real-world noiseinterference,a vehicle trajectory tracking controller based on model predictive control(MPC)integrated with theextended Kalman filter algorithm(EKF-MPC)was constructed. Firstly,a vehicle dynamics model was esta...
更多
Number of views:1081 Amount of downloads:5786
-
NI Jiahua,ZHAO Zhixing,ZHU Yinxiao,MUHAMMAD AJMALAidha,YANG Yongheng
Abstract:Regarding the practical operation of photovoltaic(PV)systems,the photo-electron conversionefficiency and degradation rate of PV modules are easily affected by several factors,e. g. ,irradiance,humidity,and temperature. Subsequently,an efficient framework for assessing power degradation became the cornerston...
更多
Number of views:1075 Amount of downloads:6175