LAI Yongbo,LU Jun,LI Huarong
Abstract: To deal with the mould quantitative casting over-pouring and spillage,based on the analysis of thetechnological process and the control characteristics for a kind of auto molten bucket casting mechanism,under the condition without depending on system concrete models,a three stages casting was proposed to r...
更多
Number of views:3077 Amount of downloads:9488
-
ZHANG Guoqiang,LI Rundong,HUANG Yuanming,DING Dawei,WANG Gaolin,XU Dianguo
Abstract: Supply interruption may occur during the operation of permanent magnet synchronous motor(PMSM)in some special applications and it needs to be restarted in the rotating state which is called flying start,the accurate initial position/speed observation is the foundation of flying start. Aiming at the problem...
更多
Number of views:3074 Amount of downloads:8436
-
XU Changbao,DING Jian,SONG Hongjian,PAN Chengda, SUN Pengbo,WANG Qihua,CHEN Hui
Abstract: An optimization method was proposed to layout electric vehicle charging facilities consideringpower quality constraints. A comprehensive power quality index model considering the average value of nodalthree-phase unbalance degree and the maximum value of nodal voltage deviation was established. Meanwhile,t...
更多
Number of views:3059 Amount of downloads:5542
-
TIAN Kai,LI Fengsheng,CHU Zilin,YU Zhibin,LI Teng,WANG Mingyue
Abstract: Aiming at the short circuit fault protection of medium voltage three-level converter with IGCT asthe core and the monitoring of changes in main circuit device parameters during operation,a method was proposed to simultaneously realize fault identification of IGCT three-level converter and monitoring of mai...
更多
Number of views:3042 Amount of downloads:7765
-
LIU Juan,HU Xiaolei,TENG Yiyina,ZHANG Shiqi,ZHANG Zhe
Abstract: Hydrogen fuel cells air compressor is an important accessory of hydrogen fuel cell,but the high costcaused by its high energy consumption hinders the further development of hydrogen fuel cell. In recent years,theindustry has gradually adopted variable frequency drives to control the operation of hydrogen f...
更多
Number of views:3037 Amount of downloads:9110
-
王德明,李英量,贾俊辉,解晨,王语园
Abstract: The conventional overcurrent protection is ineffective in isolating faults in microgrids due to the lowfault current level contributed by distributed generations(DGs). Because of its high agility and adaptability,themeasured impedance-based protection schemes are considered as common alternatives to detect...
更多
Number of views:3031 Amount of downloads:5963
-
ZHANG Guoqiang,NIU Ben,YANG Hua,WANG Gaolin,XU Dianguo
Abstract: Maximum torque per ampere(MTPA)control is one of the important methods to improve theefficiency of sensorless drive system of permanent magnet synchronous motor(PMSM). In the sensorless drivesystem,the traditional calculation method deduces the analytical solution of the optimal current vector angleaccordi...
更多
Number of views:3009 Amount of downloads:10248
-
YUAN Minxin,YIN Zhonggang,LUO Peien,ZHANG Yanqing
Abstract: To address the problem of the long detection time of the current detection method during the opencircuit fault diagnosis of inverter insulated gate bipolar transistor(IGBT)of the permanent magnet synchronousmotor(PMSM)drive system,an error current polarity method based on model predictive current control(M...
更多
Number of views:3007 Amount of downloads:10279
-
WANG Wenguang,QIU Shuming,BAI Yang,GAO Pengcheng,YU Shipeng
Abstract: Taking the steel rolling system improvement as an example,the design of 12-pulse parallel electriccontrol system of SIEMENS SINAMICS DCM 6RA80 in the steel rolling system was described in detail,as well asthe calculation and selection of main components,such as rectifier transformer,rectifier device and sm...
更多
Number of views:2998 Amount of downloads:6082
-
REN Xuan,CHEN Tong,DONG Lizhi,HUANG Lingtong,ZHANG Mingxia
Abstract:When a large number of energy storage devices are integrated into the power grid through a virtualsynchronous generator(VSG),improper selection of control parameters in traditional fixed inertia and dampingcontrol strategies can lead to long adjustment times or large overshoot,and fail to fully leverage the...
更多
Number of views:2994 Amount of downloads:7284
-
FU Yang,SIMA Chao,TIAN Shuxin,CAI Pengcheng,GU Jiping,LIU Shu
Abstract: Expected fault screening of smart distribution network is an important basis for system security situation assessment. In order to comprehensively and accurately perceive the security risk of smart distributionnetwork,a micro-synchronous phasor measurement unit(μPMU)with real-time,synchronicity,accuracy an...
更多
Number of views:2994 Amount of downloads:5421
-
ZHAN Chengkang,LI Xiaolu,LU Yiming,LIU Riliang,LI Congli
Abstract: With the access of large-scale distributed energy resources in active distribution network,thetraditional centralized control architecture system will not effectively deal with a large number of distributed unit,so it is necessary to study the optimal scheduling of distributed resource cluster in active di...
更多
Number of views:2991 Amount of downloads:6182
-
GU Jiming,SONG Yunting,LIU Xinyu,ZHU Shaoxuan,LEI Yu,ZHANG Tongzun
Abstract:Under the dual carbon background of AC and DC hybrid power grids have the new feature of"strong HVDC and weak AC system" and power electronization,in order to effectively reduce the risk of largescalepower outages in power grid,it is necessary to build a secure and reliable comprehensive defense system toen...
更多
Number of views:2987 Amount of downloads:8220
-
LIU Huichen,LI Zhen,SU Weifeng,YUWEN Bo,LI Haitao,ZHANG Zhenbin
Abstract: In the long cable driven induction motor drive systems,speed sensorless control is usually adopteddue to the long distance between the controller and the motor. In addition,long cable increases the stator sideimpedance of the induction motor,especially the equivalent stator resistance by an order of magnit...
更多
Number of views:2983 Amount of downloads:8614
-
SHI Liguo,LI Yanzhen,LI Yuanfu,GUAN Xuelin,XU Zhigen,ZHANG Mingyuan
Abstract:Three-level neutral-point-clamped(3L-NPC)interconnected converters have been widely used inthe AC-DC hybrid distribution grids due to their superiorities of large capacity and high power quality. However,their working conditions are always with high power,varying load,and limited heat dissipation,etc.,with ...
更多
Number of views:2980 Amount of downloads:7876