Download ranking
Current location:Home >Download ranking
-
LÜ Yi,LIANG Wenbo,WANG Qing,LIU Entao
Abstract: The traditional active distribution network location and capacity determination ignores the multienergycomplementary coordination characteristics of the energy system,which led to high cost. Therefore,anactive distribution network location and capacity determination method based on energy interconnection w...
更多
Number of views:2015 Amount of downloads:4696
-
ZHANG Jun,GONG Min,ZHOU Yi,XIE June,CAO Lei,LIU Yingying
Abstract:In traditional current protection,the effective value of current is compared with the setting value toidentify the fault which is the typical protection scheme for the transmission lines of the power distribution systems.The current is calculated by the fast Fourier transform algorithm. As the calculation o...
更多
Number of views:2075 Amount of downloads:4688
-
WANG Zhengqi,WEI Wei
Abstract:Flexible multi-state switch(FMSS) is a new type of power electronic device that replacestraditional tie switches and is applied to modern distribution networks. It can optimize the consumption andregulation of distributed power sources in modern distribution networks. The FMSS controlled by VSG is notaffect...
更多
Number of views:2112 Amount of downloads:4684
-
SUN Jia,HAN Shuntian,NI Lianghua,LÜ Ganyun
Abstract:While a large number of distributed generator(DG)keep penetrating into distribution networks,the problems such as voltage violation and network power congestion become more and more serious. Soft open point (SOP)can quickly achieve flexible interconnection and accurate power flow control,effectively address...
更多
Number of views:1858 Amount of downloads:4644
-
JIANG Yehai,JIAO Hao,CHEN Zhi,MA Jiayang ,LI Bin
Abstract:To improve the quality of power distribution network parameters,an abnormal parameteridentification and localization method for distribution networks based on smart meter measurements was proposed.The method transformed the nonlinear identification equation solving problem in traditional identificationalgor...
更多
Number of views:1802 Amount of downloads:4627
-
WU Zhenyu,LIU Yonghang,LIU Yuansen,ZHANG Yihan,ZHENG Yongle,ZU Wenjing
Abstract:With the proposal of the“dual carbon”goals and the development of new power systems,theproportion of renewable energy sources such as wind and solar power continues to increase,and the load volumegrows with enhanced volatility,posing higher demands on the expansion of transmission lines due to uncertainties...
更多
Number of views:506 Amount of downloads:4607
-
ZHANG He,CAO Tianbi,LI Xianyun
Abstract: In view of the complex transient characteristics of short-circuit faults in DC power network and thedifficulty of fault identification,the short-circuit faults in DC power network can be identified by detecting the change of capacitance voltage through the analysis of the VSC topology and switch characteri...
更多
Number of views:2410 Amount of downloads:4594
-
ZHANG Feifei,ZHANG Jun,WU Long,WU Xiaohui,XUE Zhanbo
Abstract: In order to solve the problems of false alarm rate and missing alarm rate in the traditional faultdetection method of substation primary equipment,a fault detection method of substation primary equipment based on deep convolution neural network was proposed. The substation primary equipment image and scene...
更多
Number of views:3315 Amount of downloads:4591
-
XU Bin,CUI Wenqing,CAO Huanxi,CHEN Peiyu,LI Qian,JIN Yu
Abstract:Driven by the dual-carbon goals,to effectively reduce the carbon emissions of flexible DCinterconnected microgrids cluster and enhance the flexibility of system control,a low-carbon control strategy wasproposed. Firstly,a topology of flexible DC interconnected microgrids cluster was proposed,and the carbone...
更多
Number of views:1043 Amount of downloads:4566
-
SUN Heyu,JI Baowei,WEI Yushan,FANG Weihan,WANG Yangyang
Abstract:In response to the problem of slow response speed of main steam pressure in the coordinated controlsystem of thermal power units,the control effect of the coordinated control system was improved by blowing outsome of the stored powder in the pulverizing system. Based on the traditional milling system model,...
更多
Number of views:1688 Amount of downloads:4561
-
ZHANG Jinbo,YAN Lei,SHI Jian,HUANG Xiaoyu,YANG Dishan,YAN Tongyu
Abstract: A large number of voltage fluctuations will occur in the grounding process of optical storage DCmicrogrid,which has a bad impact on the stability of microgrid power signal. Due to the poor voltage disturbancesignal capture ability of the present optical storage DC microgrid grounding anti-interference tech...
更多
Number of views:2830 Amount of downloads:4561
-
ZHOU Yi,FANG Wei,GONG Min,XIA Xuesong,CHEN Yanling,HAN Ni
Abstract:Despite bringing several benefits to modern power systems,distributed generation(DG)andmicrogrids cause a significant impact on the operation of power distribution networks,especially with regard to theprotection system. In this new scenario,the adoption of smart protection systems capable of incorporating ...
更多
Number of views:1608 Amount of downloads:4545
-
MA Xiaoliang
Abstract: Several problems and their solutions for industrial speed regulation applications of four kinds ofcommonly used AC- DC-AC voltage source converter were introduced. Aiming at the problems of high dU/dt, shaftcurrent and power device thermal fatigue related quantitative data were given. Three kinds of rectifi...
更多
Number of views:7301 Amount of downloads:4544
-
ZHOU Liang
Abstract:Under the change of island operation conditions,the microgrid will cause that the digital twin(DT)model cannot accurately match the source domain model when migrating,which will lead to low migrationefficiency and other problems. For this reason,an adaptive migration method of digital twins model under thes...
更多
Number of views:1939 Amount of downloads:4543
-
ZHANG Yunquan,CHEN Xuanang,GUO Xiaorui,WEN An,YE Run
Abstract:To address issues like overcurrent,power oscillations,and insufficient dynamic response intraditional virtual synchronous generator(VSG)control during grid voltage sags,an improved VSG- low voltageride through(LVRT)mode-switching control strategy for grid-forming inverters was proposed. The strategydynamica...
更多
Number of views:1172 Amount of downloads:4526