ZHANG Mingqi,YE Hong,LIANG Hao,ZHAO Bo,WANG Chao,WANG Kui
Abstract:Aiming at the problem that the circulating currents analysis of modular multilevel matrix converter(M3C)is not deep enough and the frequency component of circulating currents is not clear,the coupling process of submodule capacitor voltage fluctuation,bridge voltage fluctuation and circulating currents in M...
更多
Number of views:1121 Amount of downloads:2635
-
LU Wentao,DOU Sheng,CHEN Liangliang,YANG Fengkun,ZHOU Ruichao
Abstract:To realize the real-time charging guidance of electric vehicles and improve the charging efficiency ofcharging stations,a real-time charging guidance strategy for electric vehicles based on hierarchical deepreinforcement learning was proposed. Considering the mutual coupling characteristics of vehicle-stati...
更多
Number of views:1120 Amount of downloads:4455
-
LI Haoyuan,CHEN Guowei,LI Guanjun,WEI Lingfeng,LIN Da,WANG Xiangjin
Abstract:With the emergence of a large number of distributed power generations,various unbalanced andnonlinear loads are connected to the power grid,resulting in the distortion of the grid current,which brings adverse effects to both the power grid and electrical equipment. A multifunctional energy storage converter...
更多
Number of views:1120 Amount of downloads:2727
-
ZHAO Enlai,HU Yu,GUO Jun,SU Xinlei,LIU Pengyuan,YANG Jun
Abstract:In view of the fact that the original high-dimensional nonlinear power flow model cannot be appliedto the linear planning of distribution network,and the existing linear power flow model has the problem of weakuniversality,a calculation method of distribution network linear power flow was proposed consideri...
更多
Number of views:1119 Amount of downloads:2768
-
ZHU Yuanzhe,WANG Ling,WU Zhengrong,LÜ Hong,XIAO Fan
Abstract:In order to further improve the output performance and efficiency of the converter,a grid-connectedconverter based on heterogeneous device mixing was proposed,referred to as heterogeneous grid-connectedconverter(HGCC). The HGCC consists of two half-bridge modules based on SiC MOSFET devices,which arecross-c...
更多
Number of views:1118 Amount of downloads:2805
-
CHEN Zhong,WU Yongkang,JIANG Yang,WU Fuchao
Abstract:An optimization control strategy based BPA for doubly fed wind turbines under asymmetric faultridethrough was proposed to address the issue of low accuracy of control strategies under asymmetric faults,inorder to obtain more accurate fault control model parameters for doubly fed wind turbines under asymmetr...
更多
Number of views:1117 Amount of downloads:5591
-
CHENG Liang,DUAN Pengyang,SU Hongbang,TIAN Shengjuan,QI Xiaoxuan,YAN Shengping
Abstract:In the background of a high proportion of new energy source connected to grid,the phenomenon ofnew energy interface inverters being connected to the grid through long-distance AC lines is becoming increasinglysignificant. The traditional vector controlled weak grid connected voltage source converter(VSC)bas...
更多
Number of views:1114 Amount of downloads:2032
-
JIANG Yang,CHEN Zhong,WU Yongkang
Abstract:The permanent magnet synchronous generator(PMSG)is prone to current overstep in unbalancedgrid,which affects the reliability of grid-connected system. To solve this problem,low-voltage ride-throgh controlstrategy based on direct power control was proposed. In this strategy,the direct power inner loop was us...
更多
Number of views:1114 Amount of downloads:2204
-
ZHAO Weicheng,MA Haoyuan,HUANG Jinming,CAO Xin,KE Xingsi
Abstract:Voltage source converter(VSC)working as the interface of new energy stations connects to urbanmain network with long-distance AC line,which results a weak grid connected condition and has a risk of DCvoltage instability. To analyze the mechanism of DC voltage instability of weak grid connected VSC,a DC volt...
更多
Number of views:1113 Amount of downloads:5217
-
WANG Qi,DONG Xinsheng,HE Shan
Abstract:To address the issue of transient overvoltage at the sending end of the wind farm caused by faults inconventional high-voltage direct current systems system,the impact mechanism of DC faults on transient voltagechanges at the sending end was analyzed. It was discovered that the reactive power surplus of the...
更多
Number of views:1112 Amount of downloads:2125
-
XU Can,MIAO Shuwei
Abstract:Wind turbine condition monitoring and wind power prediction both rely heavily on power curves.Firstly,to increase the modeling accuracy of wind turbine power curves,the random forest technique was used toscreen the important variables that influence wind energy capture ability. Then,the screened variables w...
更多
Number of views:1110 Amount of downloads:2519
-
ZHU Jin,JIANG Ye,ZHONG Chonglei,XU Weihe,MAO Feng,DAI Yongzheng
Abstract:The resilience capacity of farm distribution networks primarily stems from distributed generators,such as photovoltaic and biogas systems,to withstand disturbances and facilitate load recovery as microgrids during system failures. However,the dynamic characteristics of distributed generators and the cascadi...
更多
Number of views:1107 Amount of downloads:5931
-
KE Ting,TIAN Songlin,ZHOU Hai
Abstract:In order to solve the problem of low accuracy of small substation fault diagnosis,a small substationfault diagnosis model based on cooperative game and cloud model was proposed. By analyzing the characteristicsand causes of faults,the diagnosis index system was established. Entropy method and expert weighti...
更多
Number of views:1103 Amount of downloads:2743
-
CUI Mengyu,YIN Qinglong,GUO Xudong,LÜ Tuo,HU Qifeng,LIU Zhengyan
Abstract:The VPX power standard is currently the most compatible military embedded computer standardinternationally,and its modules can stably power multiple different functional modules in the chassis. A VPXpower board based on VITA46 and VITA62 standards was designed. The design architecture,ideas,and functionsof ...
更多
Number of views:1095 Amount of downloads:2732
-
CHEN Sisi,LI Zhigang,ZHENG Jiehui
Abstract:The energy flow analysis method with both high precision and high computational efficiency is abasic tool to simulate the operation and analyze the interaction between the thermal and electric coupling systems.The traditional iterative numerical method is slow in computation,poor in computability for large-...
更多
Number of views:1095 Amount of downloads:3215