CUI Mengyu,YIN Qinglong,GUO Xudong,LÜ Tuo,HU Qifeng,LIU Zhengyan
Abstract:The VPX power standard is currently the most compatible military embedded computer standardinternationally,and its modules can stably power multiple different functional modules in the chassis. A VPXpower board based on VITA46 and VITA62 standards was designed. The design architecture,ideas,and functionsof ...
更多
Number of views:1096 Amount of downloads:2735
-
CHEN Sisi,LI Zhigang,ZHENG Jiehui
Abstract:The energy flow analysis method with both high precision and high computational efficiency is abasic tool to simulate the operation and analyze the interaction between the thermal and electric coupling systems.The traditional iterative numerical method is slow in computation,poor in computability for large-...
更多
Number of views:1095 Amount of downloads:3217
-
CHEN Biao,HAN Zhongxiu,MA Liqiang,ZHANG Renhe
Abstract:The back-to-back active neutral-point-clamped(ANPC)converter,as the core component of theunified power flow controller of the distribution network,is widely used for the flexible closed-loop operation.However,the ANPC converter has more switching devices and commutation paths,which significantly increasesth...
更多
Number of views:1094 Amount of downloads:2977
-
MA Junchao,WANG Chenxu,SUN Dan,PENG Yan,ZHANG Zeyu,YANG Ying
Abstract:In response to the potential frequency secondary drop problem of direct-drive wind power systemsin the scenario of continuous frequency drop faults in the power grid,the principle of primary frequency regulationof direct-drive wind power systems was analyzed. A primary frequency regulation control strategy ...
更多
Number of views:1092 Amount of downloads:2538
-
FANG Yong,SONG Tao,GUO Ziqiang,WANG Jian,GUO Jie
Abstract:With the continuous development of renewable energy sources and the increasing share ofrenewable energy in the grid,optimal coordination of maintenance work becomes increasingly important in order to ensure the safety of power supply in power systems considering renewable energy access. Current tools formai...
更多
Number of views:1091 Amount of downloads:2244
-
SHENG Jie,GUO Tiantian,JIA Kaili,ZHU Jianfeng,YUAN Yuan,WANG Qi
Abstract:The grid frequently exhibits weak grid characteristics because the impedance fluctuation range ofthe collector network is broad in high permeability distributed generation system. The coupling relationshipbetween the phase-locked loop and the grid impedance leads to desynchronizing between the grid-followin...
更多
Number of views:1089 Amount of downloads:2776
-
JIANG Xuejiao,ZHANG Changqing,QIN Gang,ZHONG Lei,ZHOU Chaojun,CHEN Yupei
Abstract:In order to balance the output difference between renewable energy and load in the activedistribution network and reduce the budget cost and user purchase cost,an optimal dispatching method ofdistributed generation units in the active distribution network based on power demand side response was proposed.On ...
更多
Number of views:1088 Amount of downloads:2246
-
LEI Aoyu ,LI Jun ,MEI Yong ,TONG Ning ,WANG Yu ,WU Wei
Abstract:The stability analysis of power system transient voltage,power angle,and frequency is often basedon short-time-scale electromechanical transient simulation,which requires a relatively accurate large-scalesimulation model,which not only has low simulation efficiency but also takes a long time,thus giving ris...
更多
Number of views:1086 Amount of downloads:2405
-
CHI Yuhang,ZHAO Lu,GE Qiongxuan,LIU Xue,CHENG Shi
Abstract:Taking the switch tube open-circuit fault of dual bridge series resonant DC-DC converter(DBSRC)as the research object. Firstly,the basic working principle of DBSRC was summarized,and the open circuit faultcharacteristics of DBSRC converter were introduced. On this basis,the fault characteristics that can be...
更多
Number of views:1081 Amount of downloads:3551
-
ZHANG Xuyang,ZHANG Maosong,WANG Xiuqin,CHEN Zhong,WANG Qunjing
Abstract:In view of the problem that the transfer branch of the current high-voltage DC circuit breaker mostlyadopts uncontrollable full-bridge transformer coupling energy supply,which is not conducive to controllable andstable power supply,and low energy utilization,a combined DC circuit breaker energy supply metho...
更多
Number of views:1081 Amount of downloads:2657
-
HUANG Licai,YANG Xu,ZHANG Jing,LUO Chuanxian,CHEN Jia,ZHANG Guozhi
Abstract:In view of the frequent occurrence of omissions and false alarms of partial discharge insulationdefects in on-site gas insulated switchgear(GIS),the partial discharge multi-source detection test platform was built by using true GIS to carry out the intermittent discharge test of metal contamination defect o...
更多
Number of views:1077 Amount of downloads:2068
-
CHEN Chen,DONG Pingxian,SONG Xiaofan,GUO Fang,QI Huanruo,DU Xiaotong
Abstract:After the distributed wind farm stations are integrated into the distribution network,due to thecharacteristics of wind farm short-circuit current amplitude control and frequency offset,the traditional three-stagecurrent protection of distribution network is difficult to accurately identify the fault on the...
更多
Number of views:1074 Amount of downloads:2232
-
YIN Li,SHENG Junjie,YUAN Jie,FENG Yanjun
Abstract:In the context of carbon neutrality,an optimal pricing strategy for electric vehicle charging stationsconsidering carbon emissions was proposed. Firstly,a price response characteristic model of electric vehicle userswas constructed. Secondly,an optimal pricing model with the lowest carbon emission,the minim...
更多
Number of views:1073 Amount of downloads:3489
-
MA Zun,CHEN Haoying,DENG Can,CHEN Yong,GUAN Lin
Abstract:The development of modern power systems with wide span,low inertia,and complex structuremakes the frequency stability problem increasingly prominent,and the spatial-temporal distribution characteristicsof frequency are distinct. Taking the actual power grid as the object,the impacts of large-scale new energ...
更多
Number of views:1072 Amount of downloads:2511
-
LI Xinhai,LUO Qifeng,ZENG Qingzhu,ZENG Xinxiong,YAN Chao
Abstract:The detection of composite insulator defects in substations still relies on inspection by operators,which is a heavy workload and prone to leakage due to visual fatigue. To reduce the computational resourceconsumption and shorten the training time,the region convolutional neural networks(RCNN)was improved b...
更多
Number of views:1067 Amount of downloads:2367